Top rated dry type power transformer supplier: What is the protection scope of gas protection? In oil-immersed transformers, the scope of gas protection inside the transformer mainly includes the gas content in the transformer oil. Normally, the oil in an oil-immersed transformer is used for insulation and cooling, but when the transformer fails or ages inside, gases such as gas and hydrogen will be generated, which will lead to an increase in the gas content in the oil. If the gas content in the oil is too high, it will cause the insulation performance of the oil to decrease, which will cause the transformer to malfunction or even explode. Therefore, in order to protect the safe operation of the transformer, it is necessary to monitor and control the gas content in the transformer oil. Generally speaking, the gas relay is a commonly used gas monitoring device in oil. The gas relay can monitor the change of the gas content in the oil, and send out an alarm signal when the gas concentration exceeds a certain threshold, so as to carry out repair and maintenance in time. In short, the gas protection range inside the transformer mainly refers to the gas content in the transformer oil, which needs to be monitored and controlled by devices such as gas relays to protect the safe operation of the transformer. Find more info at dry type electrical transformers manufacturers.
Rising temperature: The capacity of the transformer will decrease as the temperature rises. Therefore, it is necessary to consider the appropriate heat dissipation method and heat dissipation area when designing the transformer to ensure that the temperature rise of the transformer does not exceed the allowable range. Connection method: Different transformer connection methods, such as star, delta, etc., will also affect the capacity of the transformer. For the star connection, the capacity of the transformer can be increased by about 3 times; for the delta connection, the capacity of the transformer is relatively small. Insulation level: The insulation level of the transformer determines the insulation capability and safety performance of the transformer, and also affects the capacity of the transformer. To sum up, the capacity of the transformer is related to factors such as input voltage and output voltage, load nature, temperature rise, connection method and insulation level. When selecting a transformer, it is necessary to comprehensively consider various factors according to the actual situation to ensure the normal operation and stability of the transformer.
The consequences of poor power quality, including voltage unbalances, can be far-reaching: Random Equipment Malfunctions: Voltage sags, swells, transients, and harmonics can cause unpredictable equipment malfunctions, leading to unscheduled downtime, reduced productivity, and increased maintenance costs. Data Corruption: Poor power quality can cause errors in data processing equipment, leading to data corruption and loss of valuable information. Loss of Process Control: Voltage unbalances and other power quality issues can disrupt process control systems, affecting the quality of the output and leading to production losses. Regular monitoring is indispensable in identifying and addressing power quality issues promptly. Implementing effective strategies to manage these issues can significantly mitigate their adverse impacts. These might include investing in innovative solutions like those offered by companies such as CANWIN Automatic Equipment Co., Ltd. With their commitment to quality and innovation, such businesses play a crucial role in helping others maintain high power quality and, in turn, achieve optimal performance and longevity of their transformer equipment.
Canwin is a professional ctl line manufacturers & suppliers china, we have been specialized in ctl machines for over 20 years.This cut to length production line adopts advanced control system to ensure the accurate and stable operation of the cut to length production line. Embedded operating terminal can complete parameter setting quickly and conveniently. After the coil material of silicon steel sheet is punched and cut into certain shape and size by this cut to length production line, the classification and finishing work is completed at the end of the production line, and it is automatically stacked into 20 columns and used for the core assembly.
As a professional electrical equipment manufacturer in China, Canwin specialized in dry type transformers, electrical equipment for over 20 years. Canwin electrical products manufacturer adopts large-scale, intelligent electrical machinery equipment manufacturing mode, and strive to achieve high quality, high efficiency, low cost operation.Our electrical machinery products including cut to length lines, china slitting lines and foil winding machines.
Three-dimensional wound core transformer breaks through the traditional triangle plane structure, adopts three-phase symmetric vertical structure, magnetic circuit completely symmetrical three-phase core products, magnetic resistance is greatly reduced, excitation current, no-load loss, is a kind of using traditional materials, but lower operating noise, structure is more compact and efficient energy-saving oil type transformer. Its excellent performance in energy saving and energy saving and environmental protection is in line with China’s energy conservation policy.
The transformer coils are referred to as the primary and secondary windings. When applying AC current to the primary winding of the transformer, the transformer coil creates a pulsing magnetic field. The core of the transformer works to direct the path of the magnetic field between the primary and secondary coils to prevent wasted energy.The machine is a very powerful and versatile machine which can wind a wide range of HV coils for distribution transformers using round and rectangular wires. It is fully automatic with paper strip winding.Winding material lnsulated with an epoxy resin -environmentally friendly.
Want to find good electrical materials, please contact Canwin, a professional electrical material supplier with 20+ years of experiences. Electrical steel, also known as silicon steel sheet, is an important soft magnetic alloy indispensable to power, electronics and military industry, as well as the largest output of metal functional materials, mainly used as the iron core of various motors, generators and transformers. Silicon steel plate’s production process is complex, manufacturing technology is strict, foreign production technology is protected in the form of patent, as the life of the enterprise. Find more details at https://www.canwindg.com/
As a professional laser machine manufacturer & supplier, Canwin specialized in laser machine manufacturing, including laser welding machines and laser cutting machines.Continuous fiber laser hand-held welding equipment is a special equipment for metal processing such as hardware, building materials and handicrafts launched by CANWIN. Small equipment, easy to move and handling, flexible and convenient operation, can realize outdoor welding, suitable for all kinds of complex sheet metal hardware welding. Welding efficiency is fast.
Digital measurement – Digital measurement of transformers or other components can be conducted, and the measurement results can be called and collected from the process layer and station control layer through digital networks, thus monitoring transformers and other equipment.Status visualization – The operation status of transformers can be visualized and observed in the power grid.Smart grid or other related systems can express the status information of transformer self-detection or information interaction.
Connection group label: According to the phase relationship between the primary and secondary windings of the transformer, the transformer windings are connected into various combinations, which are called the connection group of the windings. In order to distinguish different connection groups, the clock notation is often used, that is, the phasor of the line voltage on the high-voltage side is used as the long hand of the clock, fixed at 12, and the phasor of the line voltage on the low-voltage side is used as the short hand of the clock. The number of the short hand indicates the connection group label. For example, Dyn11 indicates that the primary winding is (triangle) connected, and the secondary winding is (star) connected with a center point, and the group number is (11) points.