Hmi panel factory 2023: Object-oriented principle: That is, according to the identity characteristics and work nature of the operator, design a human-machine interface that is compatible and friendly. According to their work needs, it is appropriate to display prompts, guidance and help information in pop-up windows, so as to improve the level of user interaction and efficiency. HMI, whether for the field controller or for the upper monitoring and management, the two are closely interconnected, they monitor and manage the field equipment objects are the same, so many field equipment parameters are shared between them and passed to each other. The standardized design of the human-machine interface should be the future development direction, because it really reflects the easy-to-configure, simple, and practical principles of the base, fully expressing the human-centered design concept. A variety of industrial control configuration software and programming tools provide powerful support for the production of a beautiful human-machine interface, and the larger and more complex the system, the more it can reflect its superiority. Read even more details at switching power supply manufacturers.
Reasonable Structural Type: There are two structural types: main module and extended module. The average price of each I/O point of the integral PLC is cheaper than that of the module type, and the volume is relatively small, which is generally used in the small control system with a fixed system process; The function expansion of module plc is flexible and convenient, and there is a large choice in the number of I/O points, the ratio of input points to output points, the type of I/O modules…etc, and the maintenance is convenient, generally in more complex control systems.
Create the external model of the system function design model is mainly to consider the data structure, overall structure and process description of the software, interface design is generally only as an accessory, only the user’s situation (including age, gender, psychological situation, literacy, personality, ethnic background, etc.) have an understanding of the user to design an effective user interface; according to the end user’s hypothesis of the future system (referred to as the system hypothesis) The user model is designed to match the system image (external characteristics of the system) obtained after the system is implemented, so that the user can be satisfied with the system and can use it effectively; the information given by the system hypothesis should be fully considered when building the user model, and the system image must accurately reflect the syntactic and semantic information of the system. In short, only by understanding the user and the task can a good human-machine interface be designed.
The Third Step: Selecting Type of HMI Panel With the project and market demand and technology innovation, general resistive screen has no meet the new needs of the market and the high requirement of customers, thus deriving a new series of touch screen products, that is multi touch capacitive hmi, its high definition, highest bright, no drift, anti-scratech, supporting multi-touch to achieve special page effect. It is similar to our Apple iPhone, which is very popular in the market. If you are interested, you can have a try Mochuan Drives capacitive hmi panel type. Or to require the special operation temperature for the working environment.
Wuxi Mochuan Drives Technology Co.,Ltd is one manufacturer and system solution company. To quickly match the high advantage competitive model through industry experience and solution to bring a high value market and a new growth point for our customers. We mainly provide Hmi Panel, Hmi Touch Screen , Plc Controller and permanent magnet motor. To explore more equipment value for equipment manufacturers and end users, improve efficiency, reduce costs, optimize management, and promote equipment manufacturers’ service transformation. See extra information at mochuan-drives.com.
Typically, a heartbeat detection is used to define the BOOL, the HMI sets this point at a fixed frequency and the PLC resets when it receives a signal that the point is on. If no signal is received for that point to turn on for a period of time, e.g. 5s, the communication is considered broken. The PLC’s memory clock byte is passed to the touch panel interface, which uses a script to assign the value of this byte to an address in another PLC, which then determines whether the two scan cycles of the returned byte are the same. If so, the communication is interrupted.
The Macro instructions of HMI Human Machine Interface are based on C language and the system is developed on Linux. There are multi-types of HMI panel, mainly three types, multi touch capacitive hmi panel, plastic shell enconomic resistive hmi touchscreen panel and metal shell wide-temperature resistive touch screen and small home screen to meet different requirement from application scenarios and market needing. There are rich serial port such as rs485, rs232, rs422, ethernet etc to meet the master and slave to use. Mochuan human machine interface manufacturer suppors the size from 4.3inch to 32inch.
The plastic enconomic resistive HMI panel is very high advantage competitive series. There are multiple parameter, resolution, serial port to select for user to achieve real matching per project budget for one size. But it does not mean, this type HMI touch panel performance, resolution…etc is not in perfect but more flexible. For example, there are 800×480, 1024×600 resolution, ethernet, 2xRS485, 2xRS232, RS422 are in optional for 7inch touchscreen HMI.
Industrial grade fully enclosed embedded industrial hmi touch panel can perfectly cope with all kinds of harsh environment, but also can bring more convenient management services: Installation of embedded industrial hmi touch screen panel in the electrical room cabinet is more conducive to intelligent monitoring and management of the equipment in the electrical room. Through the touch screen monitoring display, you can monitor and detect the running temperature, power output, output power and other conditions of the electrical chassis cabinet in real time to ensure the stable and efficient operation of the electrical room.
Specifically, the two-way communication between the HCI user and the machine containing the computer, in a certain symbol and actions to achieve, such as hitting keys, moving the mouse, displaying symbols/graphics on the screen, etc. This process includes several sub-processes: identifying the interactive object – understanding the interactive object – grasping the object situation – information adaptation and feedback, etc.; and the human-machine interface is the communication media or means between the user and the machine system containing the computer, which is the software and hardware supporting the two-way information interaction between human and machine. Here the interface is defined as the media or means of communication, and its physical embodiment is the relevant supporting software and hardware, such as a graphic display terminal with a mouse, etc.